50
Counterpart User Manual
5.8
Connecting a Barcode Scanner
The
Counterpart
will accept a barcode scanner connected to the unit. In order to use a scanner, you must set the
specifications of the
Counterpart
scale to recognize the scanner to the appropriate port and in some cases, do the
setup on the scanner required by the scanner manufacturer.
The scanner allows non-contact, instantaneous, and accurate input of unit weight, tare weight, and ID code.
QD2100 Barcode Scanner
If you are using the Quickscan QD2100 barcode scanner sold by Rice Lake Weighing Systems, you can set up
the scanner by connecting the scanner (PN121495) to the RS-232 port on the
Counterpart
CPU board.You will
also need a cable (PN101555) and an AC power option for the scanner. Connections between the barcode
scanner and Counterpart should be wired up as follows:
The default baud rate is set for 9600 for both
Counterpart
and the scanner.
To set up barcode scanner parameters, use the following steps:
1. Navigate through the menu Setup >> Config >> Serial.
2. Set up the selected Port, J5 (Port 1) or J4 (Port 2) for the scanner. .
3. Follow through and set up the various parameters such as 9600 baud, 8 bits, 1 stop bit, none parity.
4. Headers are set to
ON
under the scanner submenu when needing to have headers for IDs, tare and unit
weights.
5. If the header is set to
OFF
, the
Counterpart
assumes that all items are ID codes and automatically adds
the ID code header.
5.8.1
Setting up a Softkey
To set up a softkey, use the following steps:
1. Press the
MENU SETUP
key.
2. Navigate through the menu setup to Setup using the key.
3. Press the
to navigate to
CONFIG
.
4. Press the
to navigate to
SCALES.
5. Press the to navigate to
FEATURE.
6. Press the
to navigate to
COUNT.
7. Using the scroll through until you get to
SOFTKEYS
.
8. Scroll down, then using scroll through menu selections SK1 through SK12.
9. Press to assign a softkey to that position
10. Select a choice that you wish to be displayed.
11. Press the arrow once the function is selected.
12. Press
Save/Exit
softkey.
Pin out
Wire Color
RX
Green
TX
Red
Ground
Black
DIGIO
5+
Table 5-2. Barcode Wiring Connections
Header Codes for Bar Codes
ID Code 3
Tare 4
Unit Weight 1
Table 5-3. Header Codes for Bar Codes
MENU