5 menu structures and parameter descriptions, 6 setup menu, 1 scale submenu – Rice Lake Counterpart Configurable Counting Indicator - User Manual - Version 1.0 User Manual
Page 24: Scale submenu

18
Counterpart User Manual
3.5
Menu Structures and Parameter Descriptions
The
Counterpart
scale can be configured using a series of menus accessed through the scale front panel when the
scale is in setup mode. Figure 3-5 and Table 3-3 summarizes the functions of each of the top level menus.
Figure 3-5. Top Level Configuration Menu
The
Counterpart
counting scale can be configured using a series of menus accessed through the display front
panel when the scale is in setup mode. The top level menu structure includes the following:.
3.6
Setup Menu
The setup menu allows you to configure settings for the scale, features, serial port settings, Ethernet, print
format, and digital inputs and outputs. You can also view the software and regulatory versions, and revert to
default settings.
3.6.1
SCALE Submenu
Calibration can be performed in two places within the menu: the CALIBR menu shown in Figure 3-11 is an
in-depth scale setup and calibration. A “quick access” calibration is shown in Figure 4-1 on page 39.
Menu
Menu Function
ID
ID
Sets up IDs of various parts
AUDIT
Audit Trail
View audit trail data
CALIBR
Calibration
Calibrate Counterpart through this menu
SETUP
Setup
Set up the configuration parameters
TEST
Test Menu
Test functionality
DISPLAY
Display
Sets up the display parameters of Counterpart
Table 3-3. Top Level Menu Structure
To access the second level parameters use the down arrow on the indicator to access the submenus which are
noted in Table 3-4.
Menu
Menu Function
SCALES
Configuration
Configure and calibrate scales.
FEATURE
Feature
Set date and time formats passwords, keyboard locks, regulatory mode, and initial
consecutive number value, count function, and define softkeys.
SERIAL
Serial
Configures the communications ports
ETHERNET
Ethernet
Configures the Ethernet port
PFORMT
Print Format
Set print format used for header, gross, net, count, pallet and total ticket formats. See
Section 6.0 on page 51 for more information.
DIG IO
Digital IO
Assign digital input/output functions
VERS
Version
Display installed software version number. The Reset Config softkey on the Version menu can
be used to restore all configuration parameters to their default values.
Table 3-4. Setup Menu Summary
AUDIT
CALIBR
SETUP
TEST
DISPLAY
ID
SCALES
FEATURE
SERIAL
ETHERNET
PFORMT
DIGIO
VERS
CONFIG