beautypg.com

Table-contents2 – Oldcastle BuildingEnvelope Reliance-HTC User Manual

Page 3

background image

R E L I A N C E − H T C I N S T A L L A T I O N M A N U A L

TABLE OF CONTENTS

Section 3: Glazing 15−21

3.1 Pressure Plate and SSG Gasket Installation 15
3.2 Thermal Spacer Installation 15
3.3 Interior Gasket Installation and Sealing 16
3.4 Setting Block Placement 16
3.5 Setting Glass 17
3.6 Temporary Retainer Installation 17
3.7 Side Block Installation 18
3.8 Repeat of Steps 3.3 to 3.7 18
3.9 Sealing For Vertical Pressure Plates 18
3.10 Vertical Pressure Plate Installation 20
3.11 Horizontal Pressure Plate Installation 20
3.12 Final Check of Pressure Plate Torque 20
3.13 Vertical Face Cover Installation 20
3.14 Sealing Tops of Vertical Mullions 20
3.15 Sealing Horizontal Pressure Plates 20
3.16 Horizontal Face Cover Installation 20

Section 4: Supplemental Instructions 22−30

Transition Glazing 22
Vertical Splicing 23
Entrance Frames 26
Reglazing Procedures 29
Corner Mullions 30

Section 5: Parts List 31−36

Quick Reference Guide

1. Torque pressure plate screws to 90 in−lbs (60 in−lbs at WW−333 temporary retainers)

2. Glass Sizing:

Captured System − D.L.O. + 1" for width and height.
SSG System − D.L.O. + 2" for width. D.L.O. + 1" for height.

3. Locate pressure plate screws @ 9" o.c. ( 1 1/2" from ends )
4. 1 3/4" glazing system available in two depths: 7 1/4" and 10"
5. 2" glazing system available in two depths: 7 1/2" and 10 1/2"

MAY 2013

Phone: 1-866-OLDCASTLE (653-2278)

Web Address: www.oldcastlebe.com