2 1/2"
SSG vertical
Quarter points
Quarter points
1/4" splice joint
1/2"
face cover
splice joint
118"
Face cover
(dashed)
FS−325
Butt−splice isolator
as required (seal joint)
SEALING NOTES:
1. Prior to attaching horizontal face covers, seal
between pressure plates.
2. Attach face covers and seal joint (a foam
backer rod can be used to aid in sealing)
Attachment
holes
Weep holes
1/2"
face cover
splice joint
Face cover
Pressure bar
(dashed)
Backer rod between face
cover and pressure plate
Pressure Plate Splice
Face Cover Splice
FIGURE 16
Pressure Plate/Face Cover Splicing & Sealing at SSG Mullions
(Intermediate Horizontal Shown; Head & Sill Similar)
R E L I A N C E − H T C I N S T A L L A T I O N M A N U A L