2 1/2"

SSG vertical

Quarter points

Quarter points

1/4" splice joint

1/2"

face cover

splice joint

118"

Face cover
(dashed)

FS−325

Butt−splice isolator

as required (seal joint)

SEALING NOTES:

1. Prior to attaching horizontal face covers, seal

between pressure plates.

2. Attach face covers and seal joint (a foam

backer rod can be used to aid in sealing)

Attachment

holes

Weep holes

1/2"

face cover

splice joint

Face cover

Pressure bar
(dashed)

Backer rod between face

cover and pressure plate

Pressure Plate Splice

Face Cover Splice

FIGURE 16

Pressure Plate/Face Cover Splicing & Sealing at SSG Mullions

(Intermediate Horizontal Shown; Head & Sill Similar)

R E L I A N C E − H T C I N S T A L L A T I O N M A N U A L

GLAZING

MAY 2013

19