Standards

|

65

Safety Code 6 (Canada) General Public

Frequency (f) in MHz.

Power

Density

(mW/cm

2

)

E-Field

(V/m)

H-Field

(A/m)

(MHz) E-Field

H-Field

0.003-1

C

280

2.19

1-10

C

280/f

2.19/f

10-30

C

28

2.19/f

30-300 0.2

28

0.073

300-1500 f/1500

1.585f

1/2

0.0042f

1/2

1500-40,000 1 61.4

0.163