Alarm setting, 9 alarm setting – AVer EXR5016_series user manual User Manual
Page 83
75
3.9
Alarm Setting
In the Alarm Setting dialog box, click Add to insert and set new alarm setting, click Delete to remove the
selected alarm setting, click OK to exit and save the setting, Cancel to exit without saving. Click Default will
back to factory default value.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
1. Click Add to insert and set a new alarm setting. Click the items in the (8) Alarm Setting List if you want to
modify the alarm setting.
2. In (1) No./Name/Description enter alarm name and description. Alarm No. will be created by DVR
system.
3. In (2) Enable Time, the number from 00 to 23 represent the time in 24-hour clock. Select the time and click
the block you want to activate or deactivate the alarm function. When it is deactivated the color of the block
turns white.
4. In (3) Conditions
, you can set “Trigger if any” to activate if it falls to one of the conditions or “Trigger if all”
to activate if it falls to all conditions.
5. In (4) Camera section, select and click on the camera number (01 to 16) in Motion Detected and Video
Loss to set the condition for the system to alarm.
6. In (5) Sensor, select and click on the sensor number to set the condition for the system to alarm. If the
sensor normal status is high, set the sensor condition to low.
-
IP Camera Sensor: To adjust sensor high/low that is connected on the IP camera.