Dell PowerVault 735N (Rackmount NAS Appliance) User Manual
Page 30

3-12
Installation and Troubleshooting Guide
4-2-2
Shutdown failure
Replace the system board. See
Chapter 9, “Getting Help,” for
instructions on obtaining technical
assistance.
4-2-3
Gate A20 failure
4-2-4
Unexpected interrupt in pro-
tected mode
Ensure that all expansion cards are
properly seated, and then reboot
the system.
4-3-1
Improperly seated or faulty
DIMMs
Remove and reseat the DIMMs. If
the problem persists, replace the
DIMMs. See Chapter 9, “Getting
Help,” for instructions on obtaining
technical assistance.
4-3-3
Defective system board
Replace the system board. See
Chapter 9, “Getting Help,” for
instructions on obtaining technical
assistance.
4-3-4
Time-of-day clock stopped
Replace the battery. If the problem
persists, replace the system board.
See Chapter 9, “Getting Help,” for
instructions on obtaining technical
assistance.
4-4-1
Super I/O chip failure (defective
system board)
Replace the system board. See
Chapter 9, “Getting Help,” for
instructions on obtaining technical
assistance.
4-4-2
Parallel-port test failure (defec-
tive system board)
Replace the system board. See
Chapter 9, “Getting Help,” for
instructions on obtaining technical
assistance.
4-4-3
Math coprocessor failure (defec-
tive microprocessor)
Remove and reseat the specified
microprocessor. If the problem still
persists, replace the micro-
processor. See Chapter 9, “Getting
Help,” for instructions on obtaining
technical assistance.
Table 3-2. System Beep Codes (continued)
Code
Cause
Corrective Action
NOTE: For the full name of an abbreviation or acronym used in this table, see “Abbreviations and
Acronyms.”