beautypg.com

Dell PowerVault 735N (Rackmount NAS Appliance) User Manual

Page 32

background image

3-14

Installation and Troubleshooting Guide

.

Figure 3-1. Hard-Disk Drive Indicators

Table 3-3 lists the hard-disk drive indicator patterns established by the SCSI backplane
firmware. Different patterns are displayed as hard-disk drive events occur in the sys-
tem. For example, in the event of a hard-disk drive failure, the “hard-disk drive failed”
pattern appears. After the hard-disk drive is selected for removal, the “hard-disk drive
being prepared for removal” pattern appears, followed by the “hard-disk drive ready
for insertion or removal” pattern. After the replacement hard-disk drive is installed, the
“hard-disk drive being prepared for operation” pattern appears, followed by the “hard-
disk drive online” pattern

.

Table 3-3. SCSI Hard-Disk Drive Indicator Patterns

Condition

Indicator Code

Identify hard-disk drive

All three hard-disk drive status indicators blink
simultaneously.

Hard-disk drive being pre-
pared for removal

The three hard-disk drive status indicators flash
sequentially.

Hard-disk drive ready for
insertion or removal

All three hard-disk drive status indicators are off.

Hard-disk drive being pre-
pared for operation

The hard-disk drive online indicator is on. The
drive activity light may flash briefly.

Hard-disk drive bay empty

All three hard-disk drive status indicators are off.

hard-disk drive activity indicator

hard-disk drive online indicator

hard-disk drive failure indicator

87MPGbk0.book Page 14 Wednesday, December 13, 2000 2:14 PM