Dell PowerVault 735N (Rackmount NAS Appliance) User Manual
Page 29
support.dell.com
Messages and Codes
3-11
3-1-1
Slave DMA-register failure
Replace the system board. See
Chapter 9, “Getting Help,”” for
instructions on obtaining technical
assistance.
3-1-2
Master DMA-register failure
3-1-3
Master interrupt-mask register
failure
3-1-4
Slave interrupt-mask register
failure
3-2-4
Keyboard-controller test failure
Check the keyboard cable and con-
nector for proper connection. If the
problem persists, run the keyboard
test in the Dell Diagnostics to deter-
mine whether the keyboard or
keyboard controller is faulty. If the
keyboard controller is faulty, replace
the system board. See Chapter 9,
“Getting Help,” for instructions on
obtaining technical assistance.
3-3-1
CMOS failure
Run the system board test in the
Dell Diagnostics to isolate the
problem.
3-3-2
System configuration check
failure
Replace the system board. See
Chapter 9, “Getting Help,” for
instructions on obtaining technical
assistance.
3-3-3
Keyboard controller not
detected
Replace the system board. See
Chapter 9, “Getting Help,” for
instructions on obtaining technical
assistance.
3-3-4
Screen initialization failure
Run the video test in the Dell
Diagnostics.
3-4-2
Screen-retrace test failure
3-4-3
Search for video ROM failure
4-2-1
No timer tick
Replace the system board. See
Chapter 9, “Getting Help,” for
instructions on obtaining technical
assistance.
Table 3-2. System Beep Codes (continued)
Code
Cause
Corrective Action
NOTE: For the full name of an abbreviation or acronym used in this table, see “Abbreviations and
Acronyms.”
87MPGbk0.book Page 11 Wednesday, December 13, 2000 2:14 PM