About Your Solution
Table 1-4. System Messages
Message
Causes
Corrective Actions
Alert! iDRAC6 not
responding.
Rebooting.
The iDRAC6 is not
responding to BIOS
communication either
because it is not functioning
properly or has not
completed initialization.
The system will reboot.
Wait for the system to
reboot.
Alert! iDRAC6 not
responding.
Power required
may exceed PSU
wattage.
Alert!
Continuing
system boot
accepts the risk
that system may
power down
without warning.
The iDRAC6 has hung.
The iDRAC6 was remotely
reset while system was
booting.
After AC recovery, the
iDRAC6 takes longer than
normal to boot.
Remove AC power to the
system for 10 seconds and
restart the system.
Alert! Power
required exceeds
PSU wattage.
Check PSU and
system
configuration.
Alert!
Continuing
system boot
accepts the risk
that system may
power down
without warning.
The system configuration
of processor,
memory modules,
and expansion cards may
not be supported by the
power supplies.
If any system components
were just upgraded,
return the system to the
previous configuration.
If the system boots without
this warning, then the
replaced component(s) are
not supported with this
power supply. If Energy
Smart power supplies are
installed, replace them with
High Output power supplies
to use the components.
book.book Page 36 Monday, January 24, 2011 12:24 PM