Memory tests
terminated by
keystroke.
POST memory test was
terminated by pressing the
spacebar.
Information only.
MEMTEST lane
failure detected
on x.
Invalid memory
configuration. Mismatched
memory modules are
installed.
Ensure that the memory
modules are installed in a
valid configuration.
See "General Memory
No boot device
available.
Faulty or missing optical
drive subsystem, hard drive,
or hard drive subsystem, or
no bootable USB key
installed.
Use a bootable USB key,
optical drive, or hard drive.
If the problem persists,
No boot sector on
hard drive.
Incorrect configuration
settings in System Setup
program, or no operating
system on hard drive.
Check the hard drive
configuration settings in the
System Setup program.
If necessary, install the
operating system on your
hard drive. See your
operating system
documentation.
No timer tick
interrupt.
Faulty system board.
PCIe Training
Error: Expected
Link Width is x,
Actual Link Width
is y.
Faulty or improperly
installed PCIe card in the
specified slot.
Reseat the PCIe card in the
specified slot number.
page 101. If the problem
persists, see "Getting Help"
Table 1-4. System Messages
(continued)
Message
Causes
Corrective Actions
book.book Page 40 Monday, January 24, 2011 12:24 PM