Dell PowerVault NX3500 User Manual
Page 30

30
About Your Solution
E1A15
SAS cable B
failure. Check
connection.
SAS cable B is missing
or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
E1A1D
Control panel
USB cable not
detected.
Check cable.
USB cable to the control
panel is missing or bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
E2010
Memory not
detected.
Inspect DIMMs.
No memory was detected
in the system.
Install memory or reseat
memory modules. See
E2011
Memory
configuration
failure.
Check DIMMs.
Memory detected, but is
not configurable.
Error detected during
memory configuration.
E2012
Memory
configured but
unusable.
Check DIMMs.
Memory configured, but is
unusable.
E2013
BIOS unable to
shadow memory.
Check DIMMs.
The system BIOS failed to
copy its flash image into
memory.
E2014
CMOS RAM
failure. Power
cycle AC.
CMOS failure. CMOS
RAM not functioning
properly.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
Table 1-3. LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 30 Monday, January 24, 2011 12:24 PM