beautypg.com

Dell PowerVault NX3500 User Manual

Page 30

background image

30

About Your Solution

E1A15

SAS cable B

failure. Check

connection.

SAS cable B is missing

or bad.

Reseat the cable. If the

problem persists,

replace cable.
If the problem persists,

see "Getting Help" on

page 113.

E1A1D

Control panel

USB cable not

detected.

Check cable.

USB cable to the control

panel is missing or bad.

Reseat the cable. If the

problem persists, replace

cable.
If the problem persists,

see "Getting Help" on

page 113.

E2010

Memory not

detected.

Inspect DIMMs.

No memory was detected

in the system.

Install memory or reseat

memory modules. See

"Troubleshooting System

Memory" on page 97.

E2011

Memory

configuration

failure.

Check DIMMs.

Memory detected, but is

not configurable.

Error detected during

memory configuration.

See "Troubleshooting

System Memory" on

page 97.

E2012

Memory

configured but

unusable.

Check DIMMs.

Memory configured, but is

unusable.

See "Troubleshooting

System Memory" on

page 97.

E2013

BIOS unable to

shadow memory.

Check DIMMs.

The system BIOS failed to

copy its flash image into

memory.

See "Troubleshooting

System Memory" on

page 97.

E2014

CMOS RAM

failure. Power

cycle AC.

CMOS failure. CMOS

RAM not functioning

properly.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 113.

Table 1-3. LCD Status Messages

(continued)

Code

Text

Causes

Corrective Actions

book.book Page 30 Monday, January 24, 2011 12:24 PM