beautypg.com

Dell PowerVault NX3500 User Manual

Page 29

background image

About Your Solution

29

E1714

Unknown error.

Review & clear

SEL.

The system BIOS has

determined there has

been an error in the

system, but is unable to

determine its origin.

Check the SEL for more

information and then

clear the SEL. Remove

AC power to the system

for 10 seconds and restart

the system.
If the problem persists,

see "Getting Help" on

page 113.

E171F

PCIe fatal

error on Bus

## Device ##

Function ##

The system BIOS has

reported a PCIe fatal

error on a component

that resides in PCI

configuration space at

bus ##, device ##,

function ##.

Remove and reseat the

PCIe expansion cards.

If the problem persists,

see "Troubleshooting an

Expansion Card" on

page 101.

E1810

Hard drive ##

fault. Review

& clear SEL.

The specified hard drive

has experienced a fault.

See "Troubleshooting a

Hard Drive" on page 100.

E1812

Hard drive ##

removed. Check

drive.

The specified hard

drive has been removed

from the system.

Information only.

E1920

iDRAC6 Upgrade

Failed.

iDRAC6 upgrade has

failed.

See "Getting Help" on

page 113.

E1A14

SAS cable A

failure. Check

connection.

SAS cable A is missing

or bad.

Reseat the cable. If the

problem persists,

replace cable.
If the problem persists,

see "Getting Help" on

page 113.

Table 1-3. LCD Status Messages

(continued)

Code

Text

Causes

Corrective Actions

book.book Page 29 Monday, January 24, 2011 12:24 PM