E1714
Unknown error.
Review & clear
SEL.
The system BIOS has
determined there has
been an error in the
system, but is unable to
determine its origin.
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
E171F
PCIe fatal
error on Bus
## Device ##
Function ##
The system BIOS has
reported a PCIe fatal
error on a component
that resides in PCI
configuration space at
bus ##, device ##,
function ##.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
E1810
Hard drive ##
fault. Review
& clear SEL.
The specified hard drive
has experienced a fault.
E1812
Hard drive ##
removed. Check
drive.
The specified hard
drive has been removed
from the system.
Information only.
E1920
iDRAC6 Upgrade
Failed.
iDRAC6 upgrade has
failed.
E1A14
SAS cable A
failure. Check
connection.
SAS cable A is missing
or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
Table 1-3. LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 29 Monday, January 24, 2011 12:24 PM