E2021
Incorrect
memory
configuration.
Incorrect memory
configuration.
Check screen for specific
error messages. See
E2022
General
failure
during POST.
Check screen
message.
General failure after video. Check screen for specific
error messages.
E2110
Multibit Error
on DIMM ##.
Reseat DIMM.
The memory module in
slot “##” has had a
multi-bit error (MBE).
E2111
SBE log
disabled on
DIMM ##.
Reseat DIMM.
The system BIOS has
disabled memory
single-bit error (SBE)
logging and will not log
anymore SBEs until the
system is rebooted. “##”
represents the memory
module implicated by
the BIOS.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
I1910
Intrusion
detected.
Check chassis
cover.
System cover has been
removed.
Information only.
I1911
LCD Log Full.
Check SEL to
review all
Errors.
LCD overflow message.
A maximum of ten error
messages can display
sequentially on the LCD.
The eleventh message
instructs the user to check
the SEL for details on the
events.
Check the SEL for details
on the events.
Remove AC power to the
system for 10 seconds or
clear the SEL.
I1912
SEL full.
Review & clear
log.
The SEL is full of events
and is unable to log any
more.
Check the SEL for details
on the events, then clear
the SEL.
Table 1-3. LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 33 Monday, January 24, 2011 12:24 PM