Dell PowerVault NX3500 User Manual
Page 46

46
About Your Solution
Warning: Control
Panel is not
installed.
The control panel is not
installed or has a faulty cable
connection.
Install the control panel, or
check the cable connections
between the display module,
the control panel board,
and the system board.
See "Control Panel
Warning! No micro
code update
loaded for
processor n.
Micro code update failed.
Update the BIOS firmware.
Warning! Power
required exceeds
PSU wattage.
Check PSU and
system
configuration.
Warning!
Performance
degraded. CPU and
memory set to
minimum
frequencies to
meet PSU wattage.
System will
reboot.
The system configuration of
processor, memory modules,
and expansion cards may not
be supported by the power
supplies.
If any system components
were just upgraded, return
the system to the previous
configuration. If the system
boots without this warning,
then the replaced
component(s) are not
supported with this power
supply. If Energy Smart
power supplies are installed,
replace them with the High
Output power supplies to
use the components. See
Warning! PSU
mismatch. PSU
redundancy lost.
Check PSU.
A High Output power supply
and an Energy Smart power
supply are installed in the
system at the same time.
Install two High Output or
two Energy Smart power
supplies in the system.
You can also run the system
on one power supply until
you can obtain two power
supplies of the same type.
Table 1-4. System Messages
(continued)
Message
Causes
Corrective Actions
book.book Page 46 Monday, January 24, 2011 12:24 PM