Dell PowerVault NX3500 User Manual
Page 25
About Your Solution
25
E1311
Fan module ##
RPM exceeding
range. Check
fan.
RPM of specified fan in
specified module is
outside of intended
operating range.
E1313
Fan redundancy
lost. Check
fans.
The system is no longer
fan redundant. Another
fan failure would put the
system at risk of
over-heating.
Check LCD for
additional scrolling
messages. See
E1410
Internal Error
detected.
Check "FRU X".
Specified processor has an
internal error. The error
may or may not have been
caused by the processor.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
E1414
CPU # temp
exceeding
range. Check
CPU heatsink.
Specified processor is out
of acceptable temperature
range.
Ensure that the processor
heat sink is properly
installed. See
E1418
CPU # not
detected.
Check CPU is
seated
properly.
Specified processor is
missing or bad, and the
system is in an
unsupported
configuration.
Ensure that the specified
microprocessor is
properly installed. See
E141C
Unsupported
CPU
configuration.
Check CPU or
BIOS revision.
Processor is in an
unsupported
configuration.
Ensure that your
processor matches and
conforms to the type
described in the processor
technical specifications
outlined in your system’s
Getting Started Guide.
Table 1-3. LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 25 Monday, January 24, 2011 12:24 PM