Dell PowerVault NX3500 User Manual
Page 28

28
About Your Solution
E1710
I/O channel
check error.
Review & clear
SEL.
The system BIOS has
reported an I/O
channel check.
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
E1711
PCI parity
error on Bus
## Device ##
Function ##
The system BIOS has
reported a PCI parity
error on a component
that resides in PCI
configuration space at
bus ##, device ##,
function ##.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
PCI parity
error on Slot
#. Review &
clear SEL.
The system BIOS has
reported a PCI parity
error on a component
that resides in the
specified slot.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
E1712
PCI system
error on Bus
## Device ##
Function ##
The system BIOS has
reported a PCI system
error on a component
that resides in PCI
configuration space at
bus ##, device ##,
function ##.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
Table 1-3. LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 28 Monday, January 24, 2011 12:24 PM