beautypg.com

Table 4-17, Switchshow command field descriptions -30 – Dell PowerVault 56F (16P Fibre Channel Switch) User Manual

Page 86

background image

4-30

Installation and Troubleshooting Guide

( / !!''

%

switchName

The switch name

switchType

Model number and system board revision level; the model
number is as follows:
1 = PowerVault 50F
2 = Reserved
3 = PowerVault 51F/56F

switchState

The state of this switch: online, offline, testing or faulty

switchRole

There are three possibilities for switchRole including:

Principle — The principal switch as defined in FC-SW

Subordinate — This switch is enabled and is a subordi-
nate switch

Disabled — The switch is disabled

switchDomain

The domain ID of this switch: 0 to 31 or 1 to 239

switchID

The domain ID of this switch's embedded port: hex fffc00 to
fffc7f

switchWwn

The WWN of this switch; the WWN is a unique identifier for
each switch and is assigned by the manufacturer: a numbering
scheme administrated globally ensures that this WWN is
unique to each switch

Port Number

One line per port is printed after the switch summary; each
line shows the port number: 0 to 15, the GBIC type, the port
state and a comment field

GBIC type

The GBIC type follows the port number; the five GBIC types
include:
-- — No GBIC present
sw

Shortwave GBIC

lw

Longwave GBIC

cu

Copper GBIC

id

Serial ID

This manual is related to the following products: