Issuing telnet commands, Isolating a system fault, Removing power – Dell PowerVault 56F (16P Fibre Channel Switch) User Manual
Page 100: Status and activity indicators, Front-panel led power indicators, Issuing telnet commands -2, Isolating a system fault -2, Removing power -2, Status and activity indicators -2, Front-panel led power indicators -2
5-2
Installation and Troubleshooting Guide
To retest a port which has been marked
;03, clear the port and set to %Kusing the
diagClearError <
> command. This command clears the port status only and
does not clear the logs or change the port’s condition. The diagClearError <
>
command should only be used during diagnostic procedures to reset a bad port for
retest.
For more detailed error message information, see Appendix A, “Error Messages.”
)'
Telnet commands (see Chapter 4, “PowerVault 56F 16-Port Fibre Channel Switch
Commands”) are available to determine the switch’s status, error conditions, and
switch operating statistics.
The diagnostic procedures are completed using commands during a Telnet session.
) .
Various loopback paths are built into the switch hardware for diagnostic purposes. A
loopback path test within the switch verifies the proper internal Fibre Channel Port
(FCP) logic functions and the paths between the interfaces and central memory.
#
Error messages are stored in RAM and are lost when power is removed from the
switch. Access the error message log to view and note any error messages before
removing power from the switch.
'
The following status activity indicators apply to G_Port and FL_Port interface cards.
NOTE: FL_Port interface cards have an additional green light-emitting diode (LED) (vis-
ible from the front of the switch) to identify them from G_Port interface cards.
. 6& #)
The color and flash speed of the power LED, as described in Table 5-1, indicates the
switch’s status.