Ifshow, Ipaddrset, Ifshow -21 – Dell PowerVault 56F (16P Fibre Channel Switch) User Manual

Page 77: Ipaddrset -21, Table 4-11, Ipaddrset command field descriptions -21

background image

support.dell.com

PowerVault 56F 16-Port Fibre Channel Switch Commands

4-21

#

The ifShow command displays a summary of currently running tasks. The display
includes three sections organized by interface:

— Ethernet 10/100BASE-T port

— Loopback interface

— Fibre Channel; this section is omitted if IP over Fibre Channel is not
configured

%!

The following example shows the ipAddrSet command, which sets the switch’s
Ethernet IP address, Ethernet subnetmask, Fibre Channel IP address, Fibre Channel
subnetmask, and gateway address. The fields are described in Table 4-11.

NOTE: Consult your network administrator for the appropriate IP address(es), subnet-
mask(s), and gateway address.

switch:admin> ipAddrSet

Ethernet IP Address [192.168.90.241]:

Ethernet Subnetmask [none]:

Fibre Channel IP Address [192.168.65.241]:

Fibre Channel Subnetmask [none]:

Gateway Address [192.168.90.1]:

( 0''!!''

%

Ethernet IP address

The default IP address on a new switch is a tempo-
rary number derived from the switch’s World Wide
Names (WWN); enter a valid IP address

Ethernet subnetmask

The Ethernet subnetmask value; the default subnet-
mask value is none; see your network administrator
for the appropriate subnetmask value to enter here

Fibre Channel IP address

The Fibre Channel IP address for the switch; enter a
valid IP address (not currently supported)

Fibre Channel subnet-
mask

The Fibre Channel subnetmask for the switch; the
default is none

Gateway IP address

The gateway IP address; the default gateway address
on a new switch is none; you must enter a valid gate-
way address, if required

This manual is related to the following products: