Page 154
A-18
Installation and Troubleshooting Guide
DIAG-POST_SKIPPED
(T
[switch initialization]
POST is skipped; its message
recommended that POST be
executed
Information only
None required
DIAG-REGERR
(T;5
[portRegTest, sramRetention-
Test]
Data read from ASIC register or
ASIC SRAM did not match data
previously written into same
location
ASIC failure
Replace main-
board assembly
DIAG-REGERR_UNRST
(T;5
[portRegTest, sramRetention-
Test]
Port failed to reset
ASIC failure
Replace main-
board assembly
DIAG-STATS
(T!!!5-
-!
[portLoopbackTest, crossPort-
Test]
Port counter value did not
match the number of frames
actually transmitted. Possible
counters reporting:
FramesTx: Number of frames
transmitted
FramesRx: Number of frames
received
Cl3FrmRx: Number of Class3
frames received
ASIC, GBIC mod-
ule or fiber cable
failure
Replace main-
board assembly,
GBIC module or
fiber cable
DIAG-TIMEOUT
(T!)5-)5- )
[portLoopbackTest, crossPort-
Test, centralMemoryTest]
For portLoopbackTest and
crossPortTest:
Port failed to receive frame
within timeout period
For centralMemoryTest:
Port failed to detect an inter-
rupt within the timeout period
ASIC, GBIC mod-
ule or fiber cable
failure
Replace main-
board assembly,
GBIC module or
fiber cable
DIAG-XMIT
(T!!75!75-75
- 7
[portLoopbackTest, crossPort-
Test, spinSilk, camTest]
Port failed to transmit frame
ASIC failure
Replace main-
board assembly
CONFIG CORRUPT
The switch configuration infor-
mation has become irrevoca-
bly corrupted
OS error
Contact customer
support
CONFIG OVERFLOW
The switch configuration infor-
mation has grown too large to
be saved or has an invalid size
OS error
Contact customer
support
CONFIG VERSION
The switch has encountered an
unrecognized version of the
switch configuration
OS error
Contact customer
support