Error Messages
A-15
DIAG-BUS_TIMEOUT
(T;%)5)
[portRegTest, sramRetention-
Test]
ASIC register or ASIC SRAM
did not respond to an ASIC
data access
ASIC failure
Replace main-
board assembly
DIAG-CAMINIT
(T!!-;
[camTest]
Port failed to initialize due to
one of the following reasons:
Switch not disabled
Diagnostic queue absent
Malloc failed
Chip is not present
Port is not in loopback
mode
Port is not active
Software opera-
tional setup error
or mainboard
failure
Retry, reboot or
replace main-
board assembly
DIAG-CAMSID
(T!!-"
[camTest]
ASIC failed SID NO translation
test
ASIC failure
Replace main-
board assembly
DIAG-CLEAR_ERR
(T
Port’s diag error flag (OK or
BAD) is cleared
Informational only
None required
DIAG-SMBISRF
(T!
[centralMemoryTest]
ASIC’s Central Memory
SRAMS did not complete the
BISR within the timeout period
ASIC failure
Replace main-
board assembly
DIAG-CMBISRTO
(T!
[centralMemoryTest]
ASIC’s Central Memory
SRAMS did not complete the
BISR within the timeout period
ASIC failure
Replace main-
board assembly
DIAG-CMERRPTN
(T!;
[centralMemoryTest]
Error detected at the wrong
port
ASIC failure
Replace main-
board assembly
DIAG-CMERRTYPE
(T!0
[centralMemoryTest]
Port got the wrong CMEM
error type
ASIC failure
Replace main-
board assembly
DIAG-CMICKSUM
(T!-
[cmiTest]
CMI message received failed
bad checksum test
ASIC or mainboard
failure
Replace main-
board assembly
DIAG-CMIDATA
(T!-
[cmiTest]
CMI data received did not
match date transmitted
ASIC or mainboard
failure
Replace main-
board assembly
DIAG-CMIINVCAP
(T!-
[cmiTest]
Unintended ASIC erroneously
got CMI capture flag
ASIC or mainboard
failure
Replace main-
board assembly