beautypg.com

Psshow, Psshow -27, Table 4-16 – Dell PowerVault 56F (16P Fibre Channel Switch) User Manual

Page 83: Power supply status -27

background image

support.dell.com

PowerVault 56F 16-Port Fibre Channel Switch Commands

4-27

% #

The following example shows the psShow command screen, which displays the
power supply status and manufacture information. The format of the display varies
according to the switch model and number of power supplies present.

The status of each supply is shown in Table 4-16.

After the status line, a power supply identification line may be shown. If present, this
line contains manufacture date, part numbers, serial numbers, and other information.

er_disc_c3

Receive link: the number of Class 3 frames discarded.; class 3
frames can be discarded due to timeouts or invalid/unreachable
destinations; this quantity could increment at times during nor-
mal operation but might be used for diagnosing problems in
some situations.

open

loop_open: the number of times FL_Port entered the OPEN
state.

transfer

loop_transfer: the number of times FL_Port entered the TRANS-
FER state.

opened

FL_Port opened: the number of times FL_Port entered the
OPENED state.

starve_stop

Loop tenancies stopped due to starvation

fl_tenancy

Number of times FL_Port has the loop tenancy

nl_tenancy

Number of times NL_Port has the loop tenancy

frame_nozone

Number of frames rejected due to zone protection

(

OK

Power supply present and functioning correctly

Absent

Power supply not present

Faulty

Power supply is present but faulty (no power cable,
power switch turned off, fuse blown, or other internal
error)

( !!''

%