Errshow, Errshow -16 – Dell PowerVault 56F (16P Fibre Channel Switch) User Manual
Page 72
4-16
Installation and Troubleshooting Guide
#
The errShow command displays all detected errors, one error at a time. The error log
stores the last 32 error types sensed by the switch. The log shows:
Error number (01-64)
Date and time of the first occurrence each error type was sensed
Total number of occurrences of each error type
NOTE: The maximum number of occurrences is 999.
Error type
—
Error level for each error type
—
0 = Panic (when this level is reached, the switch automatically reboots and
the display no longer shows the error)
—
1 = Critical
—
2 = Error
—
3 = Warning
—
4 = Debug
For a detailed explanation of each error type, its probable cause, and suggested cor-
rective actions, see Appendix A, “Error Messages.”
The following information is displayed in the errShow screen:
The switch detected two errors.
The task ID and task name that incurred the error (task names are displayed
using the i command). For example,
+!.
The error type, date and time, the error level, and description.
—
If there is more than one occurrence of an error type, the number of occur-
rences is shown in brackets following the error date and time.
The following is an example of the errShow command screen.