Embedded server management

error

or loose cable connection.

 

Embedded server management

is not present

 

Faulty or improperly installed

RAC or loose cable connection.

 

Ensure that the RAC is properly installed. See "

Troubleshooting Expansion Cards

" in

"Troubleshooting Your System."

 

Error: More than one RAC

detected, system halted.

 

Two RACs are installed, or

faulty or improperly installed
RAC.

 

Ensure that only one RAC is installed and that it is installed in the upper slot. Ensure that

the RAC is properly installed. See "

Troubleshooting Expansion Cards

" in "Troubleshooting

Your System."

 

Error: Remote Access Card

initialization failure.

 

Faulty or improperly installed

RAC.

 

Ensure that the RAC is properly installed. See "

Troubleshooting Expansion Cards

" in

"Troubleshooting Your System."

 

Error: RAC is not in the

correct PCI slot, system

halted.

 

The RAC is not installed in the

proper PCI slot.

 

Ensure that the RAC is installed in the upper slot. See "

Troubleshooting Expansion Cards

"

in "Troubleshooting Your System."

 

Error: RAC cannot be used

with an add-in video card

in this slot.

 

Add-in video card is installed.

 

Remove the add-in video card. See "

Installing and Removing a CERC SATA RAID Controller

"

in "Installing System Components." To use the add-in video card, remove the RAC.

 

Gate A20 failure

 

Faulty keyboard controller

(faulty system board).

 

See "

Getting Help

."

 

General failure

 

Operating system corrupted or

improperly installed.

 

Reinstall the operating system.

 

Hard disk controller

failure

 

Incorrect configuration settings

in System Setup program.

 

Run the System Setup program to correct the settings. See "Using the System Setup

Program" in your User's Guide.

 

Faulty or improperly installed

hard drive, or loose power
cable.

 

Ensure that the hard-drive subsystem is properly installed. See "

Troubleshooting Hard

Drives

" in "Troubleshooting Your System" for the type of hard drive installed in your system.

 

Invalid memory

configuration detected.

Potential corruption

exists!

 

Memory module installation

guidelines have not been
properly followed.

 

Ensure that the memory modules are properly populated. See "

Memory Module Installation

Guidelines

" in "Installing System Components."

 

Keyboard controller

failure

 

Faulty keyboard controller

(faulty system board).

 

See "

Getting Help

."

 

Keyboard data line failure

 

Keyboard failure

 

Keyboard stuck key failure

 

Loose or improperly connected

keyboard cable; faulty
keyboard; faulty keyboard
controller.

 

Ensure that the keyboard is properly connected. If the problem persists, replace the

keyboard. If the problem persists, see "

Troubleshooting the System Board

" in

"Troubleshooting Your System."

 

Memory address line

failure at address, read

value expecting value

 

Memory double word logic

failure at address, read

value expecting value

 

Memory odd/even logic

failure at start address

to end address

 

Memory write/read failure

at address, read value

expecting value

 

Faulty or improperly installed

memory modules, or faulty
system board.

 

Ensure that all memory modules are properly installed. See "

Troubleshooting System

Memory

" in "Troubleshooting Your System." If the problem persists, see "

Troubleshooting

the System Board

."

 

 

Faulty application program.

 

Restart the application program.