beautypg.com

Dell DX6000G User Manual

Page 36

background image

36

About Your System

Alert! iDRAC6 not
responding.
Rebooting.

The optional iDRAC6 is not

responding to BIOS

communication either

because it is not functioning

properly or has not

completed initialization.

The system will reboot.

Wait for the system to

reboot.

Alert! iDRAC6 not
responding.
Power required
may exceed PSU
wattage.
Alert!
Continuing
system boot
accepts the risk
that system may
power down
without warning.

The optional iDRAC6

has hung.
The optional iDRAC6 was

remotely reset while system

was booting.
After AC recovery, the

optional iDRAC6 takes

longer than normal to boot.

Remove AC power to the

system for 10 seconds and

restart the system.

Alert! Node
Interleaving
disabled! Memory
configuration
does not support
Node
Interleaving.

The memory configuration

does not support node

interleaving, or the

configuration has changed

(for example, a memory

module has failed) so that

node interleaving cannot be

supported. The system will

still run, but without node

interleaving.

Ensure that the memory

modules are installed in a

configuration that supports

node interleaving. Check

other system messages for

additional information for

possible causes. For memory

configuration information,

see "General Memory

Module Installation

Guidelines" on page 111.

If the problem persists,

see "Troubleshooting System

Memory" on page 148.

Table 1-2. System Messages

(continued)

Message

Causes

Corrective Actions

book.book Page 36 Wednesday, December 22, 2010 2:13 PM