Dell PowerEdge R210 User Manual
Page 7
SATA port x device error.
Sector not found.
Seek error.
Seek operation failed.
Faulty hard drive or USB medium or device.
Replace the USB medium or device. Ensure that the USB is
properly connected. See
Troubleshooting a USB Device
or
Troubleshooting a Hard Drive
for the appropriate drive(s)
installed in your system.
Shutdown failure.
General system error.
See
Getting Help
.
The amount of system memory has changed.
Memory has been added or removed or a
memory module may be faulty.
If memory has been added or removed, this message is
informative and can be ignored. If memory has not been
added or removed, check the SEL to determine if single-bit or
multi-bit errors were detected and replace the faulty memory
module. See
Troubleshooting System Memory
.
The following DIMMs should match in
geometry: x,x,...
Invalid memory configuration. The specified
memory modules do not match in size,
number of ranks, or number of data lanes.
Ensure that the memory modules are installed in a valid
configuration. See
General Memory Module Installation
Guidelines
.
The following DIMMs should match in rank
count: x,x,...
The following DIMMs should match in size:
x,x,...
The following DIMMs should match in size
and geometry: x,x,...
The following DIMMs should match in size
and rank count: x,x,...
Thermal sensor not detected
on x.
A memory module without a thermal sensor
is installed in the specified memory slot.
Replace the memory module.
System Memory
.
Time-of-day clock stopped.
Faulty battery or faulty chip.
See
Troubleshooting the System Battery
.
Time-of-day not set - please run SETUP
program.
Incorrect Time or Date settings; faulty system
battery.
Check the Time and Date settings. See
Using the System
Setup Program and UEFI Boot Manager
. If the problem
persists, replace the system battery. See
System Battery
.
Timer chip counter 2 failed.
Faulty system board.
See
Getting Help
.
TPM configuration operation honored.
System will now reset.
A Trusted Platform Module (TPM)
configuration command has been entered.
The system will reboot and execute the
command.
Information only.
TPM configuration operation is pending.
Press (I) to Ignore OR (M) to Modify to
allow this change and reset the system.
WARNING: Modifying could prevent
security.
This message displays during system restart
after a TPM configuration command has been
entered. User interaction is required to
proceed.
Enter I or M to proceed.
TPM failure.
A TPM function has failed.
See
Getting Help
.
Unable to launch System Services image.
System halted!
System halted after F10 keystroke because
System Services image is either corrupted in
the system firmware or has been lost due to
system board replacement.
Restart the system and update the USC repository to the
latest software to restore full functionality. See the USC user
documentation for more information.
The iDRAC6 Enterprise card flash memory
may be corrupted.
Restore the flash memory using the latest version on
support.dell.com. See the iDRAC6 user's guide for instructions
on performing a field replacement of the flash memory.
Unexpected interrupt in protected mode.
Improperly seated memory modules or faulty
keyboard/mouse controller chip.
Reseat the memory modules. See
Troubleshooting System
Memory
. If the problem persists, see
Getting Help
.
Unsupported CPU combination.
Unsupported CPU stepping detected.
Processor is not supported by the system.
Install a supported processor. See
Processor
.
Unsupported DIMM detected. The following
DIMM has been disabled: x
Invalid memory configuration. The system will
run but with the specified memory module
disabled.
Ensure that the memory modules are installed in a valid
configuration. See
General Memory Module Installation
Guidelines
.
Unsupported memory configuration. DIMM
mismatch across slots detected: x,x,...
Invalid memory configuration. Memory
modules are mismatched in the specified
slots.
Ensure that the memory modules are installed in a valid
configuration. See
General Memory Module Installation
Guidelines
.
Warning: A fatal error has caused system
reset! Please check the system event log!
A fatal system error occurred and caused the
system to reboot.
Check the SEL for information that was logged during the
error. See the applicable troubleshooting section in
Troubleshooting Your System
for any faulty components
specified in the SEL.
Warning: Control Panel is not installed.
The control panel is not installed or has a
faulty cable connection.
Install the control panel, or check the cable connections
between the display module, the control panel board, and the
system board. See
Control Panel Assembly
.
Warning! No micro code update loaded for
processor n.
Micro code update failed.
Update the BIOS firmware. See
Getting Help
.
Warning! Performance degraded. CPU and
memory set to minimum frequencies to meet
PSU wattage. System will reboot.
The system configuration of processor,
memory modules, and expansion card may
not be supported by the power supplies.
If any system components were just upgraded, return the
system to the previous configuration. If the system boots
without this warning, then the replaced component(s) are not
supported with this power supply. See
Power Supply
.
Warning! Unsupported memory configuration
detected. The memory configuration is not
optimal. The recommended memory
configuration is:
Invalid memory configuration. The system will
run but with reduced functionality.
Ensure that the memory modules are installed in a valid
configuration. See
General Memory Module Installation
Guidelines
. If the problem persists, see
Troubleshooting
System Memory
.