beautypg.com

Capturing the state information – Dell PowerVault MD3200i User Manual

Page 258

background image

256

Troubleshooting: Your Storage Array Software

Capturing the State Information

Use the Troubleshooting Capture State Information option to capture

information about the current state of your storage array and save the

captured information to a text file. You can then send the captured

information to your Technical Support representative for analysis.
Potential to cause an unresponsive storage array – The State Capture option

can cause a storage array to become unresponsive to both the host and the

storage management station. Use this option only under the guidance of your

Technical Support representative.

1 From the AMW, select Advanced Troubleshooting Capture State

Information.

2 Read the information in the Confirm State Capture dialog, and type yes

to continue.

3 In the Specify filename text box, enter a name for the file to be saved, or

browse to a previously saved file if you want to overwrite an existing file.
Use the convention filename.dmp for the name of the file. The suffix

.dmp is added to the file automatically if you do not specify a suffix for the

file.

4 Click Start.

NOTE:

Each test shows a status of Executing while it is in progress. The test

then shows Completed when it successfully finishes. If any of the tests cannot

be completed, a status of Failed is displayed in the Execution summary

window.

5 Monitor the progress and completion status of all of the tests. When they

finish, click

OK to close the State Capture dialog.

Clicking Cancel stops the state capture process, and any remaining tests

do not complete. Any test information that is generated to that point is

saved to the state capture file.

NOTE:

For more information on troubleshooting and recovering from failures,

see the PowerVault Modular Disk Storage Manager online help topics.

book.book Page 256 Tuesday, June 18, 2013 3:15 PM

This manual is related to the following products: