Configuration: premium feature, Upgrading to, High-performance-tier – Dell PowerVault MD3200i User Manual
Page 189
Configuration: Premium Feature—Upgrading to High-Performance-Tier
187
13
Configuration: Premium Feature—
Upgrading to High-Performance-
Tier
The High Performance Tier premium feature on an MD3200i Series array
increases the performance of the system beyond that of a MD3200i Series
array operating at the standard performance level.
If this feature is ordered, a Premium Feature Activation card is placed in the
box with the storage array. After reading the information below, follow the
instructions on the card to obtain a key file and enable the feature.
CAUTION:
Loss of data access – The storage array automatically restarts when
the High-Performance-Tier feature is enabled or disabled. During the restart, data
is unavailable. Data availability is restored when the array restarts.
To upgrade from a standard-performance-tier storage array to a high-
performance-tier storage array, you enable the high-performance-tier
premium feature, using the Dell PowerVault Modular Disk Storage
Management (MDSM) software.
When the high performance tier feature is enabled or disabled the array
restarts. During this time, data access and management access to the
controller is temporarily lost.
It is recommended that all I/O to the array be stopped before this feature is
enabled or disabled.
While the array is restarting the state of the array in the MDSM application
may change from Optimal to Unresponsive. When the restart completes, the
status returns to Optimal.
When the array status returns to Optimal, verify that all communication
sessions are reestablished. If any sessions are not automatically reestablished
you must reestablished the sessions manually.
When all communication sessions to the array are ready, I/O to the array can
be restarted.
book.book Page 187 Tuesday, June 18, 2013 3:15 PM