Troubleshooting system cooling problems, Troubleshooting a fan – Dell PowerEdge 700 User Manual
Page 47

9.
."
10.
Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
If the problem persists, see "
Getting Help
."
Troubleshooting System Cooling Problems
Problem
l
Cooling fan is not operating properly.
l
Systems management software issues a fan-related error message.
Action
Ensure that none of the following conditions exist:
l
Ambient temperature is too high.
l
Front and back external airflow is obstructed.
l
Cables inside the system obstruct airflow.
l
An individual cooling fan has failed. See "
Troubleshooting a Fan
Problem
l
Systems management software issues a fan-related error message.
Action
1.
Run the appropriate online diagnostic test. See "
Using Server Administrator Diagnostics
" in "Running System Diagnostics."
2.
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3.
."
4.
Lay the system on its right side.
5.
6.
Ensure that the fan cables are properly connected to the fan connectors on the system board.
To identify the system board connectors, see
Figure A
-3
.
7.
."
8.
Stand the system upright.
9.
."
10.
Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
If the problem persists, replace the faulty fan. See "
System Fans
" in "Installing System Options."
If the problem is not resolved after a replacement fan is installed, see "
Getting Help
."
CAUTION:
See your System Information Guide for complete information about safety precautions, working inside the computer, and protecting
against electrostatic discharge.