System Messages

 

System messages appear on the screen to notify you of a possible problem with the system.

Table 2

-5

lists the system messages that can occur and the

probable cause and corrective action for each message.

 

 

 

Table 2-5. System Messages 

NOTE:

If you receive a system message that is not listed in

Table 2

-5

, check the documentation for the application that is running when the message

appears or the operating system's documentation for an explanation of the message and recommended action.

Message

Causes

Corrective Actions

 

Address mark not found

 

Faulty CD/diskette-drive subsystem or hard-drive

subsystem; faulty system board.

 

See "

Troubleshooting a Diskette Drive

," "

Troubleshooting a CD, DVD,

or CD-RW/DVD Drive

," "

Troubleshooting SCSI Hard Drives

," or

"

Troubleshooting SATA Hard Drives

" in "

Troubleshooting Your System

."

 

Alert! Back system fan was

not detected.

 

Specified fan is missing, faulty, or improperly

installed.

 

See "

Troubleshooting System Cooling Problems

" in "

Troubleshooting

Your System

."

 

Alert! Front system fan was

not detected.

 

Alert! Cover was previously

removed.

 

The chassis has been opened.

 

Information only.

 

Alert! DIMM(s) n are

unsupported

 

BIOS detected DIMM SPD contains invalid value or

SPD checksum failed.

 

Replace the defective memory module. See "

Memory Modules

" in

"

Installing System Options

."

 

Alert! Invalid

configuration! When using a

single hard disk drive, SATA

Port 0 must be used.

 

SATA hard drive not connected to correct

connector on system board.

 

If the system is configured with one hard drive, ensure that the drive's

interface cable is connected to the SATA PORT0 connector on the
system board. See

Figure A

-3

for connector location.

 

Alert! Mismatched DIMMs are

detected in bank(s): Bank n

 

Memory modules installed in the specified bank

are not the same type and size; faulty memory
module(s).

 

Ensure that all banks contain memory modules of the same type and

size and that they are properly installed. If the problem persists, see
"

Troubleshooting System Memory

" in "

Troubleshooting Your System

."

 

Alert! Previous back system

fan failure.

 

Specified fan failed before last system startup.

 

Information only.

 

Alert! Previous front system

fan failure.

 

Alert! Previous thermal

event.

 

BIOS detected a thermal event before the last

system startup.

 

Ensure that thermal grease is applied to the heat sink and the heat

sink is installed properly. Ensure that the front and back system fans
are functioning properly. See "

Replacing the Processor

" in "

Installing

System Options

" and "

Troubleshooting System Cooling Problems

" in

"

Troubleshooting Your System

."

 

Alert! Previous voltage

failure.

 

ESM detected sensor voltage out of range before

last system startup.

 

Information only.

 

Amount of available memory

limited to 256 MB!

 

OS Install Mode is enabled in the System Setup

program.

 

Disable OS Install Mode in the System Setup program (see "Using the

System Setup Program" in your User's Guide).

 

Auxiliary device failure

 

Loose or improperly connected mouse or

keyboard cable; faulty mouse or keyboard.

 

See "

Troubleshooting the Mouse

" and "

Troubleshooting the Keyboard

"

in "

Troubleshooting Your System

."

 

BIOS Update Attempt Failed!

 

Remote BIOS firmware update attempt failed.

 

Retry the BIOS firmware update (see "

Getting Help

").

 

Caution! NVRAM_CLR jumper is

installed on system board.

Please run setup.

 

NVRAM_CLR jumper is installed.

 

Remove the NVRAM_CLR jumper (see

Figure A

-2

for jumper location).

Check the System Setup configuration settings (see "Using the System
Setup Program" in your User's Guide).

 

 

Faulty diskette, diskette drive, CD drive, tape

 

Replace the diskette. If the problem persists, see "

Troubleshooting a