Dell PowerEdge 700 User Manual
Page 28

Data error
drive, or hard drive.
Diskette Drive
," "
Troubleshooting a CD, DVD, or CD-RW/DVD Drive
,"
"
Troubleshooting SATA Hard Drives
," or "
Troubleshooting SCSI Hard
Drives
" in "
Troubleshooting Your System
."
Decreasing available memory
Faulty or improperly installed memory modules.
See "
Troubleshooting System Memory
" in "
Troubleshooting Your
System
."
Diskette drive n seek
failure
Incorrect configuration settings in the System
Setup program.
Run the System Setup program to correct the settings (see "Using the
System Setup Program" in your User's Guide).
Faulty or improperly installed diskette drive.
See "
Troubleshooting a Diskette Drive
" in "
Troubleshooting Your
System
."
Diskette read failure
Faulty or improperly inserted diskette.
Replace the diskette.
Diskette subsystem reset
failed
Faulty or improperly installed diskette drive.
See "
Troubleshooting a Diskette Drive
" in "
Troubleshooting Your
System
."
Diskette write protected
Diskette write-protect feature activated.
Move the write-protect tab on the diskette to the disabled position.
Drive not ready
Diskette missing or improperly inserted in diskette
drive.
Reinsert or replace the diskette.
Embedded server management
error
Faulty or improperly installed remote access
controller (RAC) or loose cable connection.
Ensure that the RAC's cable is properly connected. Ensure that the
RAC is properly installed. See "
Expansion Cards
" in "
Installing System
Options
." If the problem persists, see "
Getting Help
."
Error: More than one RAC
detected, system halted.
Two RACs are installed, or faulty or improperly
installed RAC.
Ensure that there is only one RAC installed and that it is installed in
the correct slot. Ensure that the RAC is properly installed. See
"
Expansion Cards
" in "
Installing System Options
." If the problem
persists, see "
Getting Help
."
Error: RAC cannot be used
with an add-in video card in
this slot.
Add-in video card is installed.
Ensure that the RAC is installed in the correct slot. See "
Expansion
Cards
" in "
Installing System Options
."
Error: RAC is not in the
correct PCI slot, system
halted.
The RAC card is not installed in the proper PCI
slot.
Ensure that the RAC is installed in the correct PCI slot. See
"
Troubleshooting Expansion Cards
" in "
Troubleshooting Your System
."
Error: Remote Access Card
initialization failure.
Faulty or improperly installed RAC.
Ensure that the RAC is properly installed. See "
Troubleshooting
Expansion Cards
" in "
Troubleshooting Your System
."
Gate A20 failure
Faulty keyboard controller; faulty system board.
See "
Getting Help
."
General failure
Operating system corrupted or improperly
installed.
Reinstall the operating system.
Hard disk controller failure
Incorrect configuration settings in System Setup
program; improperly installed hard drive; loose
interface or power cable; faulty hard-drive
controller subsystem.
Run the System Setup program to correct the drive type setting (see
"Using the System Setup Program" in your User's Guide). If the problem
persists, see "
Troubleshooting SCSI Hard Drives
" or "
Troubleshooting
SATA Hard Drives
" in "
Troubleshooting Your System
."
Invalid memory configuration
detected. Potential
corruption exists!
Memory module installation guidelines have not
been properly followed.
See "
Memory Module Installation Guidelines
" in "
Installing System
Options
."
Keyboard controller failure
Faulty keyboard controller; faulty system board.
See "
Getting Help
."
Keyboard data line failure
Loose or improperly connected keyboard cable;
faulty keyboard; faulty keyboard controller.
See "
Troubleshooting the Keyboard
" in "
Troubleshooting Your
System
."
Keyboard failure
Keyboard stuck key failure
Memory address line failure
at address, read value
expecting value
Faulty or improperly installed memory modules.
See "
Troubleshooting System Memory
" in "
Troubleshooting Your
System
."