Page 29

Memory double word logic
failure at address, read
value expecting value
Memory odd/even logic
failure at start address to
end address
Memory write/read failure at
address, read value
expecting value
Memory allocation error
Faulty application program.
Restart the application program.
Memory bank population
error!
Memory module installation guidelines have not
been properly followed.
See "
Memory Module Installation Guidelines
" in "
Installing System
Options
."
Memory parity interrupt at
address
Faulty or improperly installed memory modules.
See "
Troubleshooting System Memory
" in "
Troubleshooting Your
System
."
Memory tests terminated by
keystroke
The spacebar was pressed during POST to
terminate the memory test.
Information only.
No boot device available
Faulty or missing CD/diskette-drive subsystem,
hard drive, or hard-drive subsystem.
Use a bootable diskette, CD, or hard drive. If the problem persists, see
"
Troubleshooting a Diskette Drive
," "
Troubleshooting a CD, DVD, or CD-
RW/DVD Drive
," "
Troubleshooting SATA Hard Drives
," or
"
Troubleshooting SCSI Hard Drives
" in "
Troubleshooting Your System
."
No boot sector on hard- disk
drive
No operating system on hard drive.
Check the hard-drive configuration settings in the System Setup
program (see "Using the System Setup Program" in your User's Guide).
No timer tick interrupt
Faulty system board.
See "
Getting Help
."
Non-system disk or disk
error
Faulty diskette, CD/diskette-drive subsystem, or
hard-drive subsystem.
See "
Troubleshooting a Diskette Drive
," "
Troubleshooting a CD, DVD,
or CD-RW/DVD Drive
," "
Troubleshooting SATA Hard Drives
," or
"
Troubleshooting SCSI Hard Drives
" in "
Troubleshooting Your System
."
If the problem persists, see "
Getting Help
."
Not a boot diskette
No operating system on diskette.
Use a bootable diskette.
PCI BIOS failed to install
Loose cable(s) to expansion card(s); faulty or
improperly installed expansion card.
Ensure that all appropriate cable(s) are securely connected to the
expansion card(s). If the problem persists, see "
Troubleshooting
Expansion Cards
" in "
Troubleshooting Your System
."
Plug & Play Configuration
error
Error encountered while initializing PCI devices.
Install the NVRAM_CLR jumper and reboot the system (see
Figure A
-2
for jumper location). If the problem persists, see "
Troubleshooting
Expansion Cards
" in "
Troubleshooting Your System
."
Primary drive n
configuration error
Primary drive n failure
Faulty or improperly installed hard drive.
Ensure that the CD drive cables are properly connected. See
"
Troubleshooting a CD, DVD, or CD-RW/DVD Drive
" in "
Troubleshooting
Your System
."
Primary drive n not found
The specified drive on the primary channel of the
integrated hard drive controller is set to Auto in
the System Setup program, but no drive is
attached; improperly installed hard drive; loose
interface or power cable.
Run the System Setup program to correct the drive settings (see
"Using the System Setup Program" in your User's Guide). If the problem
persists, see "
Troubleshooting SATA Hard Drives
" or "
Troubleshooting
SCSI Hard Drives
" in "
Troubleshooting Your System
."
Read fault
Faulty diskette, CD/diskette-drive subsystem, or
hard-drive subsystem.
See "
Troubleshooting a Diskette Drive
," "
Troubleshooting a CD, DVD,
or CD-RW/DVD Drive
," "
Troubleshooting SATA Hard Drives
," or
"
Troubleshooting SCSI Hard Drives
" in "
Troubleshooting Your System
."
If the problem persists, see "
Getting Help
."
Requested sector not found
Reset failed
Improperly connected diskette drive, tape drive,
hard drive, or power cable.
Ensure that all cables are securely connected. If the problem persists,
see "
Getting Help
."