beautypg.com

Install lock channels, Activate fold solenoid valves, Begin folding – Great Plains 1625AHL Operator Manual User Manual

Page 35

background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Operating Instructions

31

2014-04-21

Table of Contents

Index

411-020M

Install Lock Channels

Only wing (gauge wheel) lock cylinders need to be
installed for transport. The center is adequately
supported by the wing hooks and locks when folded.

For servicing, or to hold at lift when unfolded, also install
center section lift locks (see page 102)

Refer to Figure 19 (depicting a similar model YP1630F)
8.

Remove lift cylinder transport lock channels from
their storage positions.

9.

Place transport lock channels on lift cylinders
located on gauge wheels.

Activate Fold Solenoid Valves

Refer to Figure 20
10. Set Hydraulic Selector Marker/Fold switch to

“Fold”

. This opens the solenoid valves for tongue

lock, fold cylinders and caster arm cylinders.

Begin Folding

Crushing Hazard:
Keep all persons away from frame sections during lift and
lower. Area under row units is particularly dangerous. Sharp
coulter and opener blades descend with hundreds of pounds of
down-force.

11. Extend the fold cylinders and fold the planter until the

wing hooks are about 1 m (3 ft.) from the lock
assembly on the tongue.

Figure 19

Transport Cylinder Locks in Use

34550

Figure 20

Hydraulic Selector Switches

34522
36230

F

F