beautypg.com

Great Plains 1625AHL Operator Manual User Manual

Page 102

background image

98

1625AH

Table of Contents

Index

Great Plains Manufacturing, Inc.

411-020M

Table of Contents

Index

2014-04-21

General Troubleshooting

Problem

Cause

Solution

Population
Alarms

See “Seed Population Troubleshooting Charts” on page 91.

Excess Seed
Remaining

See “Seed Population Troubleshooting Charts” on page 91.

Field size different.

After ruling out population problems, re-check
geography.

Excessive gaps between planter passes.

Adjust marker, page 68.

Seed
Consumption
Too High

See “Seed Population Troubleshooting Charts” on page 91.

Field size different.

After ruling out population problems, re-check
geography.

Excessive overlap.
Irregular shaped field.

Adjust marker, page 68.

Rows Not
Planted

If not detected by seed monitor, check for
plugged row-unit seed tube

Lift planter, expose bottom of seed tube and clean out.

Uneven seed
spacing

See “Seed Population Troubleshooting Charts” on page 91.

Excessive field speed.

Reduce field speed.

Unclean seed.

Use clean seed.

Damaged seed tube

Inspect; repair or replace.

Seed-Lok

®

plugging.

Lock up Seed-Lok

®

, page 85.

Row-unit discs not turning.

See “Row-unit discs not turning freely.” in this
Troubleshooting chart.

Plugged row-unit seed tube.

Lift up planter, expose bottom of seed tube and clean
out.

Worn/rusted sprockets and/or chain idler
or bearings.

Check and replace any worn/rusted sprockets or chain
idlers.

Lack of proper seed lubrication on seed.

See “Seed Lubricants” on page 128.

Planter does
not fold or
unfold fully

Fold cylinders out of phase

Re-phase cylinders, refer to page 32

Air in lines

Bleed fold circuit, refer to page 115

Uneven seed
depth

Excessive field speed.

Reduce field speed.

Planting conditions too wet.

Wait until drier weather.

Incorrect coulter depth setting.

See coulter manual or set unit mounted coulter.

Excessive or improper row unit down
pressure spring setting.

Adjust down-pressure (page 71).

Damaged seed tubes.

Check seed tubes for damage.

Row-unit not penetrating low spots.

Adjust row-unit, see instructions beginning on page 71.

Rough planting conditions.

Rework the field.

Seed firmer not in place and set to correct
tension.

See “Seed Firmer Adjustments” on page 85.

This manual is related to the following products: