beautypg.com

Hopper entry – Great Plains 1625AHL Operator Manual User Manual

Page 112

background image

108

1625AH

Table of Contents

Index

Great Plains Manufacturing, Inc.

411-020M

Table of Contents

Index

2014-04-21

Hopper Entry
Normal use of the hopper and routine maintenance do
not require entry. The hopper vent tube structure
includes features to aid emergency egress. It is not
intended for routine entry. However, do not remove the
vent tube structure, as it is required for
pressure-balancing the space above the material.
A hopper that is full or merely appears full can be an

entrapment hazard. You can sink entirely into the material,
or into a void, and suffocate in a matter of seconds. Bridges
and crusts are especially dangerous.

You can be overcome by hazardous fumes very quickly even

in an empty hopper with the lid open.

A partially full hopper, even with no bridging present, is a

suffocation risk.
Oxygen levels may be insufficient and/or
dust levels may be too high for breathing.

Do not enter a hopper for loading material.
Do not enter a hopper for unloading material.
Do not enter a hopper for routine cleaning.
Do not enter a hopper for any meter maintenance.
Never enter a hopper without at least one trained and

equipped attendant present.

Never enter a hopper for any reason unless you fully comply

with applicable laws, regulations, rules, agreements, and
the instructions in this section. Where applicable laws,
regulations, rules, agreements contradict an instruction
below, do not follow that instruction.

+

Rapid Suffocation Hazard:
Encrusted material may be loose and flowing beneath the
crust. Any hollow spaces are highly likely to have insufficient
oxygen and/or toxic gases from microbial action and/or
chemical reactions. Falling through a crust in either case can
result in death in a matter of seconds. Never enter a hopper to
dislodge a crust or bridge.

This manual is related to the following products: