411-020M

Low Pressure, at
Desired Rate

Orifice size too large

Choose alternate orifice plate size based on charts in Seed Rate
Manual
(411-020B).

Orifices correct plate call size,
but their holes are enlarged
from extended use

Obtain new plates in the desired size. Discard worn plates.

Rate may actually be low

Check fertilizer transmission Driving/Driven sprockets.

Uneven Flow, at
Desired Rate

One or more orifice plates
plugged

Clean and re-installed orifice plates. Check that materials are not
too viscous or granular for the orifice size.

Plate sizes vary between rows Check that all nozzles have the same size plates (with the

possible exception of outside rows serving zone coulters).

Pressure
Unstable

Strainer clogged

Close all valves. Inspect strainer (See Seed Rate Manual
(411-020B)). Clean screen as needed. Switch to a larger screen
size if materials clog strainer rapidly (and large size orifices are in
use).

Dumping at
Normal Pressure

Relief valve setting too low

Review relief valve setting per Seed Rate Manual (411-020B).

High Pressure, at
Desired Rate

Orifice size too small

Review orifice sizing. If at recommended size, try the next large
size. Charts are based on typical density/viscosity materials.

Plugged nozzles

Inspect low-flow rows, or several nozzles. Clean plates. Consider
smaller strainer screen size and/or large orifice plate size.
Sedimentation, coagulation, particulates, foreign matter can also
cause unusually high pressure.

Orifice plates inverted

Orient plates with legends facing outlet. Orifice port holes are not
symmetrical, and at smaller sizes this can cause slightly higher
back-pressure with denser materials.

Very High
Flow

Fertilizer transmission in High
Range when Low Range was
intended.

Swap sprockets at transmission. See Seed Rate Manual
(411-020B).

Various possible pump issues

Refer to Trouble Chart in CDS-John Blue

®

LM-1250/LM-1255

Parts and Instruction manual, part number 12-M-43.

Pump Leaks

Various possible pump issues

Refer to Trouble Chart in CDS-John Blue

®

LM-1250/LM-1255

Parts and Instruction manual, part number 12-M-43.

Pump Oil
Consumption

Pump seals or O-ring

Refer to Trouble Chart in CDS-John Blue

®

LM-1250/LM-1255

Parts and Instruction manual, part number 12-M-43.

Noisy Pump

Crankcases components worn Refer to Trouble Chart in CDS-John Blue

®

LM-1250/LM-1255

Parts and Instruction manual, part number 12-M-43.

Liquid Fertilizer Troubleshooting

Problem

Cause

Solution

This manual is related to the following products: