VIEW MENU

VIEW Menu (1 of 2)

Mode

Item Field

Range

Access

Description

1
2
4
5

0:01 to 24:00 hr

LTD

USEr

InST

ADV

OCCUPIED TIME

SECTION B, E, I

Displays the amount of time left on the manual
override. The setpoint device operates at the
Occupied temperature and then reverts back
Scheduled temperature. Time counts down to
0:00 hours.
Cancel the override by pressing the Up and Down
buttons together at the same time or through the
user switch or gateway.

Note:

This item is only available when a

programmable setback schedule or normally
unoccupied has been selected.

1
4

-31 to 266°F

(-35.0 to 130.0°C)

SEC

LTD

USEr

InST

ADV

SETPOINT

SECTION A, D

Displays the measured setpoint sensor
temperature.

2

-31 to 266°F

(-35.0 to 130.0°C)

SEC

LTD

USEr

InST

ADV

HOT TUB

SECTION

B

Displays the measured hot tub temperature.

3

-31 to 266°F

(-35.0 to 130.0°C)

SEC

LTD

USEr

InST

ADV

DHW TANK

SECTION

C

Displays the measured indirect domestic hot
water tank temperature.

5

-31 to 266°F

(-35.0 to 130.0°C)

SEC

LTD

USEr

InST

ADV

FLOOR

SECTION

E

Displays the measured floor temperature.

6

-31 to 266°F

(-35.0 to 130.0°C)

SEC

LTD

USEr

InST

ADV

POOL

SECTION

F

Displays the measured pool temperature.

The VIEW menu items display the current operating
temperatures and status information of the system.

Continued on next page.

Display Menus