beautypg.com

tekmar 091 Sensor Socket User Manual

Installation & operation manual, 090_d

background image

Snow /Ice Sensor 090/094, Sensor Socket 091

Installation & Operation Manual

090_D

01/14

Snow Melting Replaces: 07/09

© 2014

090_D - 01/14

1 of 8

A Watts Water Technologies Company

The tekmar Snow / Ice Sensor 090 / 094
and tekmar Sensor Socket 091 are used
with all tekmar snow / ice melt controls.
The 090 has a 65’ (20 m) cable while the
094 has a 208’ (63 m) cable.
The Snow / Ice Sensor is designed to sit
flush with the slab surface after being

mounted into the Sensor Socket. The
socket is installed directly into the snow
melt slab halfway between the heating
elements or pipes.
The sensor measures the slab temperature,
sensor surface temperature and sensor
surface moisture level.

Snow/Ice Sensor 090/094

Snow/Ice Sensor Socket 091

3–7/16"

(87 mm)

1–3/4"

(45 mm)

3/16"

(5 mm)

090 Cable length 65' (20 m)

094 Cable length 208' (63 m)

Ø 7/8" (22 mm)

3–13/16"

(97 mm)

3–1/8" (80 mm)

3–1/2" (89 mm)

3/4"

(19 mm)

Snow/Ice Sensor 090/094

Automatic snow/ice detection
Slab temperature sensing
Long wire included so in field splicing
is not necessary
Designed for long life in driveway and
walkway installations
For use with tekmar Snow Melting
Control type: 654, 661, 662, 664, 665
or 667.



Snow/Ice Sensor Socket 091 Features

Provides mounting solution for
Snow/Ice Sensor 090/094
Includes mounting plate

This manual is related to the following products: