Table D.1 XM-121A Measuring Case Absolute with Accelerometer (100 mV/g)
Maximum Vibration Level
Full Scale Setting
Max High Frequency Peak Amplitude
mils pp
micrometers pp
0.8Hz HPF
2Hz HPF
4Hz HPF
23.8Hz HPF
(g pk)
5 125
0.0013
0.003
0.006
0.036
4
10
250
0.0026
0.006
0.012
0.072
4
20
500
0.007
0.02
0.04
0.24
4
50
12500
0.014
0.04
0.08
0.4
12
Table D.2 XM-121A Measuring Case Absolute with Velocimeter (100 mV/ips)
Maximum Vibration Level
Full Scale Setting
mils pp
micrometers pp
0.8Hz HPF
2Hz HPF
4Hz HPF
23.8Hz HPF
5
125
0.1
10
250
0.2
20
500
0.3
50
12500
1
Max Vibration Level (mils pp)
Max High Freq Peak Amplitude (g) 19530 freq^2
⁄
×
=
Table D.3 XM-121A Measuring Shaft Relative with Displacement Sensor (200 mV/mil)
Maximum Vibration Level
Full Scale Setting
mils pp
micrometers pp
0.8Hz HPF
2Hz HPF
4Hz HPF
23.8Hz HPF
5
125
1
10
250
2.5
15
375
4
20
500
5
50
12500
10