5–28
Configuring PanelView Operator Terminals
Publication 2711E-821 – January 1998
The following table shows the behaviour of the terminal at
power-up:
If the terminal is powered up with:
then the terminal powers up in:
the Software Mode Switching option
disabled
the mode indicated by the hardware
keyswitch
the Software Mode Switching option
enabled, and the hardware key switch in
Run Mode
the same mode it was in at power down
the Software Mode Switch option enabled
and the hardware keyswitch in Configure
Mode
Configure Mode
The Software Mode Switch button also lets you enable or disable the
Run Mode button on the Terminal Configuration screen.
•
Enable
ĊIf you enable the software mode switch, operators can
switch the terminal from Run mode to Configure mode using the
Goto Configure Mode button. Also the Run Mode button on the
Terminal Configuration screen is enabled.
•
Disable
ĊIf you disable the software mode switch, the Goto
Configure Mode button is disabled, and the Run Mode button on
the Terminal Configuration screen is disabled. The Disable
setting is the default.
Press the Time and Date button on the Terminal Configuration screen
to open the Time and Date screen.
For PanelView keypad terminals, the following Time and Date
screen is shown.
Setting Time and Date