Connect power, Functional ground screw, Secure cables – Rockwell Automation 6176M-xxxx Standard Industrial Monitors User Manual User Manual
Page 23
Rockwell Automation Publication 6176M-UM001D-EN-P - December 2012
23
Installation
Chapter 2
Connect Power
With the AC power adapter, the monitor can use a single-phase AC power
supply, providing 90…264V AC at 47…63 Hz. Use only the AC adapter supplied
with the monitor.
Power must be available at a nearby grounded outlet. Whenever possible, connect
the monitor to the same AC power source that supplies the computer.
Follow these steps to connect power to the monitor.
1. Connect the supplied AC power adapter cable to the power input
connector on the monitor (A).
2. Secure this connection by screwing the barrel over the threads (B).
3. Connect the AC power cord to the main power supply (C).
Functional Ground Screw
Using the functional ground screw is not required for safety and regulatory
compliance. However, you can use the functional ground screw on the rear panel
of the monitor if a supplemental ground is desired.
Secure Cables
Use optional cable ties to organize the monitor cables and secure them to the
cable restraints on the back of the monitor. Organizing your cables provides
easier access and identification.
Cat. No.
Description
6189V-MPS3
Replacement AC power adapter
B
A
C
Optional
Cable
Ties
Monitor Cables
Cable Restraints on Back of Monitor