Selecting export address types, Enter – Rockwell Automation 9323-PA2E APS SLC 500 Import/Export Utility User Manual User Manual
Page 32

Exporting APS Documentation/Archive Files
4-7
Selecting Export Address Types
After selecting [F10] – SELECT TYPES from the export options screen, APSIE
displays the following window, labeled “Select Export Address Types.”
SLC–500 APS IMPORT/EXPORT UTILITY
Press a Function Key
EXPORT OPTIONS
Labels
ESC exits/ALT–U aborts changes
SELECT EXPORT ADDRESS TYPES
Outputs
YES
Inputs
NO
Status
YES
Bit/Binary
YES
Timer
NO
Counter
YES
Control
NO
Integer
YES
Float
NO
M0
NO
M1
YES
String
NO
ASCII
NO
Labels
YES
From this screen you select which address types in the ASCII documentation file
you want to export.
Use the up– and down–arrow cursor keys to move through the address types
displayed in the window, highlighting those types you wish to change.
Tables 4.C and 4.D provide you with two options for configuring the address types:
table 4.C explains how you can change the status of each address type one at a time;
table 4.D explains how you can configure the export utility so that all or none of the
address types are exported.
Note
After you have configured the address types, you can save the configuration
permanently by pressing [F9] – SAVE CONFIG from the Export Options window.