Selecting import options, Preface, Aps import/export utility user manual 3-4 – Rockwell Automation 9323-PA2E APS SLC 500 Import/Export Utility User Manual User Manual
Page 21

Preface
APS Import/Export Utility User Manual
3-4
Selecting Import Options
After selecting [F5] – SELECT OPTIONS from the main import menu, the
import/export utility displays the Import Options window.
Rockwell Software Incorporated, Copyright 1989–19
9323 – PA2E
All Rights Reserved
File Names
TXT
TXT
TXT
TXT
Exists
SLC–500 APS IMPORT/EXPORT UTILITY
Press a Function Key
IMPORT
SOURCE
DESTIN:
IMPORT OPTIONS
ESC exits/ALT–U aborts changes
ASCII ARCHIVE FILE OPTIONS
F3 Ignore SLC Archive Errors
NO
ASCII PROGRAM DOCUMENTATION FILE OPTIONS
F5 On Collisions
DISCARD
F6 Default Keyword
SYMBOL
F7 Ignore TXT Documentation Errors
YES
F9 Save Configuration
ESC e
C:\IPDS\TEXT\SLC500
This screen offers you options for configuring the import of both ASCII archive and
documentation files. The function keys for this screen, with the exception of [F9] –
SAVE CONFIG, toggle through all the possible values for a given option.
For example, the “Ignore TXT Documentation Errors” option: Function key [F7] –
IGN TXT ERRORS toggles between the values “yes” and “no”, which are the only
possible values for this option.
Note
APSIE can import online edit INSERT, REPLACE, and DELETE rungs. You can
only create these rungs with an SLC 5/03 or SLC 5/04 processor. For more details
on the use of these rungs, see the Advanced Programming Software User Manual.
Select import options from table 3.B.