Go to table 7.c, Able 7.c lists diagnostic codes, Able 7.c, and other references – Rockwell Automation 1771-PM , D17716.5.18 U MNL 1771-PM CLUTCH/BRAKE MOD User Manual
Page 98: Able 7.c, Troubleshooting chapter 7
Troubleshooting
Chapter 7
7Ć14
Table 7.C
Diagnostic Message Codes Associated with the "0D" Message Code
MISCELLANEOUS MESSAGES
HEX
CODE
TYPE
PROBLEM
CORRECTIVE ACTION
01
N
IMPROPER MODE SELECTION
The PM module expects to see one of the allowable press
modes (off, inch, microĆinch, single, continuous, within 0.1 sec's
after swingarm power is sealed in, and will only allow one mode
at any given time.
Check selector switch wiring in figure 6.10 and operation.
Check wiring to swingĆarm. Check I/O module for correct
operation.
02
N
ALL STATIONS BYPASSED
In the single stroke or continuous mode, the PM will not allow the
press to cycle if all operator run stations are bypassed. At least
one station must be present. Inch and microĆinch modes will
operate with all run stations bypassed.
Check station wiring in figures 6.11 and 6.12. Check
swingĆarm wiring and I/O module for proper operation.
03
N
SHAFT NOT AT TOP. CAN NOT ENTER SINGLE OR
CONTINUOUS MODE
The PM is selected to go into the single or continuous mode, but
the cam switches, which indicate shaft position, are telling the
PM that the press is not at the top.
Check for proper cam settings in figure 5.1. Check for
proper cam wiring in figure 6.9. Inch press to the top
position.
04
N
AWAITING RELEASE OF ALL RUN BUTTONS FOR ENTERING
SINGLE OR CONTINUOUS MODES
Release all run buttons. Check for proper operation of all
buttons. Check button wiring in figures 6.11 and 6.12.
05
N/L
MAIN MOTOR FORWARD CONTACT DROPOUT OR ABSENT
The main motor forward input needs to be on in order to enter
single or continuous modes. Once in single or continuous mode,
the press will stop if that input goes off.
Check feedback contact and wiring in figure 6.10. Check
swingĆarm wiring and I/O module for proper operation.
06
N
ACAM OPEN, PREVENTING ENTRY INTO SINGLE OR
CONTINUOUS MODE.
Check wiring of ACAM in figure 6.9 and check ACAM
07
N
AWAITING RELEASE OF ALL STOPĆONĆTOP BUTTONS FOR
ENTERING CONTINUOUS MODE.
You must release STOPĆONĆTOP buttons of all active stations
before the PM can switch to another mode of press operation.
Check RUN button wiring figures 6.11 and 6.12.
08
N
AWAITING RELEASE OF ARM CONTINUOUS BUTTON FOR
ENTERING CONTINUOUS MODE.
You must release the ARM CONTINUOUS button and press the
RUN buttons of all active stations before the PM can switch to
continuous mode.
Check ARM CONTINUOUS button wiring figure 6.10.
09
L
BARRIER GUARD DROPOUT OR ABSENT.
Press stops operation.