Rockwell Automation 1771-PM , D17716.5.18 U MNL 1771-PM CLUTCH/BRAKE MOD User Manual
Page 117
Troubleshooting
Chapter 7
7Ć33
diagnostic message codes are displayed by indicators connected to module group 5, slot 1 (figure 6.18), or by displaying the corresponding
data table word using the industrial terminal.
Use this table in conjunction with figure 7.1 and figure references shown in parentheses.
Type of Message
N = NonĆlatched
L = Latched
T = Trip Condition
Code
P = at PowerĆup
Alt = Alternate chassis
Ethr = Either chassis
Top = Top chassis
Bot = Bottom chassis
Binary
Hex
Type
Code
Diagnostic Message (figure References)
1011 1100
BC
T
Air pressure signal present though air pressure feedback is not configured.
1011 1101
BD
T
Air pressure signal on when triacs are off.
1011 1110
BE
T
Air pressure signal on when triacs are on.
1011 1111
BF
T
Air pressure signal remains after triacs turn off.
Triac Fault
1100 0000
C0
T
Ethr
Triac 0 on when commanded off.
1
1100 0001
C1
T
Ethr
Triac 1 on when commanded off.
1
1100 0010
C2
T
Ethr
Triac 2 on when commanded off.
1
1100 0011
C3
T
Ethr
Triac 3 on when commanded off.
1
1100 0100
C4
T
Ethr
Triac 6 on when commanded off.
1
1100 0101
C5
T
Ehtr
Triac 7 on when commanded off.
1
1100 0110
C6
T
Bot
Triac 0 on when commanded off.
1
1100 0111
C7
T
Bot
Triac 1 on when commanded off.
1
1100 1000
C8
T
Bot
Triac 2 on when commanded off.
1
1100 1001
C9
T
Bot
Triac 3 on when commanded off.
1
1100 1010
CA
T
Bot
Triac 6 on when commanded off.
1
1100 1011
CB
T
Bot
Triac 7 on when commanded off.
1
1100 1100
CC
T
Top
Triac 0 off when commanded off.
1
1100 1101
CD
T
Top
Triac 1 off when commanded off.
1
1100 1110
CE
T
Top
Triac 2 off when commanded off.
1
1100 1111
CF
T
Top
Triac 3 off when commanded off.
1
1101 0000
D0
T
Top
Triac 6 off when commanded on.
1