Rockwell Automation 1771-PM , D17716.5.18 U MNL 1771-PM CLUTCH/BRAKE MOD User Manual
Page 127

Bit Monitoring Address
Appendix A
AĆ4
Module Group 2
Slot 0, 1771-IA, Figures 6.1 and 6.2 or 6.5 and 6.6
Addresses
Term.
Function
PLC-2/30
Chassis
A B
PLC-3
Chassis
A B
0
Input from Main Valve Stem (NO)
Switch A*
Switch B*
1a2/00
1b2/00
10ab2/00
10ac2/00
1
Input from Motion Detector (NO)
Contacts A*
Contacts B*
1a2/01
1b2/01
10ab2/01
10ac2/01
2
Input from Air Pressure (NO)
Switch A*
Switch B*
1a2/02
1b2/02
10ab2/02
10ac2/02
3
Power Monitor, Mod Grp 3, Slot 0
Chassis A
Chassis B
1a2/03
1b2/03
10ab2/03
10ac1/03
4
Crowbar Test Input
Crowbar A
Crowbar B
1a2/04
1b2/04
10ab2/04
10ac2/04
5
Not Used
6
Feedback from Press Interlock Switch
1a2/06
1b2/06
10ab2/06
10ac/06
7
Input from Aux. Valve Stem (NO)
Switch A*
Switch B*
1a2/07
1b2/07
10ab2/07
10ac/07
* Optional
Slot 1,1771-IA, Figure 6.3 or 6.7
Addresses
Term.
Function
PLC-2/30
Chassis
A B
PLC-3
Chassis
A B
0
Feedback input from Triac 0 Chassis A
1a2/10
1b2/10
10ab2/10
10ac2/10
1
Feedback input from Triac 0 Chassis B
1a2/11
1b1/11
10ab/211
10ac2/11
2
Feedback input from Triac 1 Chassis A
1a2/12
1b2/12
10ab2/12
10ac2/12
3
Feedback input from Triac 1 Chassis B
1a2/13
1b2/13
10ab2/13
10ac2/13
4
Feedback input from Triac 2 Chassis A
1a2/14
1b2/14
10ab2/14
10ac2/14
5
Feedback input from Triac 2 Chassis B
1a2/15
1b2/15
10ab2/15
10ac2/15
6
Feedback input from Triac 3 Chassis A
1a2/16
1b2/16
10ab2/16
10ac2/16
7
Feedback input from Triac 3 Chassis B
1a2/17
1b2/17
10ab2/17
10ac2/17