Rockwell Automation 1771-PM , D17716.5.18 U MNL 1771-PM CLUTCH/BRAKE MOD User Manual
Page 118
Troubleshooting
Chapter 7
7Ć34
diagnostic message codes are displayed by indicators connected to module group 5, slot 1 (figure 6.18), or by displaying the corresponding
data table word using the industrial terminal.
Use this table in conjunction with figure 7.1 and figure references shown in parentheses.
Type of Message
N = NonĆlatched
L = Latched
T = Trip Condition
Code
P = at PowerĆup
Alt = Alternate chassis
Ethr = Either chassis
Top = Top chassis
Bot = Bottom chassis
Binary
Diagnostic Message (figure References)
Code
Type
Hex
1101 0001
D1
T
Top
Triac 7 off when commanded on.
1
1101 0010
D2
T
Ethr
Triac 0 off when commanded on.
1
1101 0011
D3
T
Ethr
Triac 1 off when commanded on.
1
1101 0100
D4
T
Ethr
Triac 2 off when commanded on.
1
1101 0101
D5
T
Ethr
Triac 3 off when commanded on.
1
1101 0110
D6
T
Ethr
Triac 6 off when commanded on.
1
1101 0111
D7
T
Ethr
Triac 7 off when commanded on.
1
1101 1000
D8
T
Top
Triac 0 remains on after turned off.
1
1101 1001
D9
T
Top
Triac 1 remains on after turned off.
1
1101 1010
DA
T
Top
Triac 2 remains on after turned off.
1
1101 1011
DB
T
Top
Triac 3 remains on after turned off.
1
1101 1100
DC
T
Top
Triac 6 remains on after turned off.
1
1101 1101
DD
T
Top
Triac 7 remains on after turned off.
1
Fault in Valve Stem Feedback
1101 1110
DE
T
Main valve stem signal on when triacs are off.
1
1101 1111
DF
T
Alt
Main valve stem signal on when triacs are off.
1
1110 0000
E0
T
Aux. valve stem signal on when triacs are off.
1
1110 0001
E1
T
Alt
Aux. valve stem signal on when triacs are off.
1
1110 0010
E2
T
Dump valve stem signal on when traics are off.
1
1110 0011
E3
T
Alt
Dump valve stem signal on when traics are off.
1
1110 0100
E4
T
Main valve stem signal off when triacs are on.
1
1110 0101
E5
T
Alt
Main valve stem signal off when triacs are on.
1