Troubleshooting chapter 7 – Rockwell Automation 1771-PM , D17716.5.18 U MNL 1771-PM CLUTCH/BRAKE MOD User Manual
Page 89
![background image](/manuals/579936/89/background.png)
Troubleshooting
Chapter 7
7Ć5
3. Determine the input or device causing the fault from the
section/sub-section heading in Table 7.D where the fault code was
tabulated and from other figures or tables referred to.
4. Interpret the messages. Was this output supposed to be on? Was that
device supposed to be off?
Figure 7.3
Troubleshooting Flowchart for Diagnostic diagnostic message codes
Press will not run.
Is a diagnostic message
displayed?
See Table 7.C
Does the problem relate to an
input switch or connection?
Yes
No
No
12291
Does the problem relate to a
solenoid or its triac?
No
Take action according to Table
Is a blown fuse indicator on for
any 1771ĆOD module? (See
Replace the fuse.
No
Replace the 1771ĆOD module or
the solenoid. Check solenoid
wiring.
Yes
Yes
Does the status indicator for the
input to the 1771ĆIA module
respond correctly? (See Figure
Yes
Replace the 1771ĆIA module.
No
Replace the input switch or
check its wiring.
Warning: To guard against injury to personnel, open and lock the main power disconnect before adjusting, replacing, or repairing any
mechanical or electrical component in your press system. This consists of the press, clutchbrake, controller, and all associated wiring and
control panels.