Figure 5.7, From figure 5.7, Voting processor firmware chapter 5 – Rockwell Automation 1771-PM , D17716.5.18 U MNL 1771-PM CLUTCH/BRAKE MOD User Manual
Page 51
Voting Processor Firmware
Chapter 5
5Ć12
Figure 5.7
Operational Sequence for First Upstroke and Second Downstroke in Continuous Mode
First Upstroke.
Both voting processors continue
actuating the clutch for the first
upstroke
Has an operator released a RUN
button, or has the barrier guard
opened?
Is the shaft in the nearĆtop
position?
Select inch mode and position the
shaft near the top.
NOTE: HalfĆstroke or StrokeĆandĆaĆhalf requires all operators to hold all RUN buttons until the first
or second downstroke is completed. Releasing a RUN button during the (first) upstroke requires
restarting continuous mode at the arming sequence. Releasing a RUN button in the first or second
downstroke requires restarting as if an operator had stopped the press in the first downstroke.
12266
Yes
Did the shaft stop in the
nearĆbottom position?
Has 1/2 or 1 1/2 stroke been
configured?
Yes
No
Both voting processors continue
actuating the clutch for the
second downstroke
Has an operator released a RUN
button, or has a barrier guard
opened?
No
Yes
Select Continuous Mode
No
Yes
No
Go to
Continuous
Stroking
Go to
Stop Condition
Yes
No
Both voting processors
de-energized their solenoid
triacs to stop the press.